X40133S1-I 40KW Rectifier AC/DC Charging Module

X40133S1-I 40KW Rectifier AC/DC Charging Module

Model: X40133S1-I
Output Voltage: 150-1000Vdc
Input Voltage: 260-485Vac
Constant Output Power: 40kW @300-1000Vdc
Dimension (W*D*H): 300mm × 437mm × 84mm
Weight: ≤17.5kg

Send Inquiry

Product Overview

Powered by cutting-edge SiC technology and innovative hardware-software synergy, the X40133S1-I is a high-performance unidirectional AC/DC charging module. It stands out with its robust adaptability, superior weighted efficiency, and ultra-quiet, smart operation, effectively boosting the reliability and uptime of charging infrastructure. With its unique zero standby power consumption, it empowers charging piles to achieve top-tier energy efficiency ratings, creating maximized value for operators and a better experience for users.

Key Features

High Efficiency——Optimized gate drive circuits and component upgrades, improving average full-load efficiency by ≥1%. Peak efficiency of 97.4%.
Intelligent Operation——Predictive maintenance/Life-cycle prediction for key components (via XYBR Power protocol). Detection and early warning for grid anomalies, such as voltage dips and weak grid conditions.
Enhanced Reliability——Upgraded core components (e.g., capacitors) ensure superior long-term reliability. Patented air duct layout reduces the temperature rise of key components by 10-20°C.
0 Standby Consumption——Integrated relay on the AC input side achieves true "zero power" standby.

Technical Specifications

DC Output
Output Voltage150-1000Vdc
Max Output Current133.3A
Constant Output Power40kW @300-1000Vdc
Voltage Regulation Accuracy≤±0.5%
Current Regulation Accuracy≤±1%
Voltage Ripple Factor≤1%
Current Sharing Unbalance≤±5%
Conversion EfficiencyPeak Efficiency: 97.4%; Weighted Efficiency: 97%
AC Input
Input Voltage260-485Vac
Input Connection3W+PE
Input Frequency50/60Hz ±5Hz
THDi≤3% @100% Load
Power Factor≥0.99 @100% Load
Protection
Module Over-temperatureAutomatic shutdown; auto-recovery to standby once temperature returns to normal.
Input Over/under-voltage, Phase LossAutomatic shutdown; auto-recovery to standby once input returns to normal.
Over-current, Short CircuitAuto-shutdown with latch-off
Output Over-voltageDual software and hardware protection
Communication
Communication InterfaceCAN
Max Connection Quantity60 Units
Address SettingDual-mode address setting via software or keypad.
Operation Condition
Operation Temperature-40-75℃, derating @Temp.>55℃
Relative Humidity≤95% RH, NC
Altitude2000m, derating @alt.>2000m
Cooling MethodForce-air cooling
General Specifications
Dimension (W*D*H)300mm × 437mm × 84mm
Weight≤17.5kg
Standy Power0W/0Var @ external input relay drive
Noise≤63dB @rated condition
MTBF>500,000 hours

Performance Chart

Application Scenarios

Urban Public Fast-charging Stations
Commercial Complexes
Battery Swapping Stations
Highway Charging Stations
Specialty Vehicle Charging Stations