ISO 15118-20 Explained: V2G, Bidirectional Charging and SECC Requirements

As electric vehicle charging technology develops, communication between EVs and charging stations is becoming increasingly important. ISO 15118-20 is one of the key standards supporting this development, particularly in bidirectional charging and Vehicle-to-Grid (V2G) applications.

For EV charger manufacturers, understanding this standard is important when developing next-generation charging equipment and selecting compatible SECC controllers.

What Is ISO 15118-20?

ISO 15118-20 is an international standard that defines communication between electric vehicles (EVs) and electric vehicle supply equipment (EVSE).

Published in April 2022, it introduces the second-generation network and application layer requirements for EV charging communication.

Compared with ISO 15118-2, ISO 15118-20 expands the communication framework and defines communication procedures for bidirectional power transfer. It also covers wireless power transfer and communication for automatic connection devices.

Here is a simplified comparison:

FeatureISO 15118-2ISO 15118-20
GenerationFirst generationSecond generation
EV-to-EVSE communicationSupportedSupported
Plug & ChargeSupportedSupported
Bidirectional power transferNot defined as a complete bidirectional communication frameworkCommunication procedures defined
Wireless charging communicationNot covered in the same expanded frameworkCovered

The main development is not simply a new communication version. ISO 15118-20 provides a broader framework for advanced charging services and bidirectional energy transfer.

How Does ISO 15118-20 Enable V2G Charging?

Traditional EV charging mainly follows a one-way energy flow: electricity moves from the grid to the vehicle.

With bidirectional charging, energy can also flow from the vehicle back to an external system.

Common applications include:

  • G2V (Grid-to-Vehicle): Electricity flows from the grid to the EV.

  • V2G (Vehicle-to-Grid): The EV sends electricity back to the grid.

  • V2H (Vehicle-to-Home): The EV supplies power to a home.

  • V2B (Vehicle-to-Building): The EV supplies power to a building.

ISO 15118-20 defines the communication procedures needed for bidirectional power transfer, allowing the vehicle and charging equipment to exchange the relevant charging and discharging information.

However, an important point for equipment manufacturers is that ISO 15118-20 support alone does not make a charging station V2G-capable.

A complete V2G solution also requires compatible bidirectional power electronics, vehicle support, system-level control, and compliance with applicable grid connection requirements.

The Role of SECC in ISO 15118-20 Communication

SECC (Supply Equipment Communication Controller) is installed on the charging equipment side, while EVCC (Electric Vehicle Communication Controller) operates on the vehicle side.

These two controllers communicate to coordinate the charging process.

In a typical CCS charging system, the communication process involves the following steps:

  1. The vehicle connects to the charging equipment.

  2. The EVCC and SECC establish a communication session.

  3. The two controllers exchange charging parameters and service information.

  4. The charging system manages the agreed power transfer process.

For manufacturers developing ISO 15118-20-compatible equipment, the SECC should be evaluated in several areas:

Evaluation AreaWhat to Check
ISO 15118-20 SupportConfirm whether the SECC supports ISO 15118-20 and which communication functions are implemented.
AC/DC Charging CompatibilityCheck whether the SECC supports the required AC or DC charging architecture and corresponding communication processes.
Communication InterfaceVerify support for PLC communication and compatibility with the charging system's hardware interfaces.
TLS and Certificate ManagementCheck support for secure communication, TLS and the certificate-related functions required by the application.
V2G CommunicationFor bidirectional charging applications, confirm that the SECC supports the relevant ISO 15118-20 V2G communication processes.
Interoperability TestingAsk whether the SECC has undergone interoperability testing with compatible EVs, EVCCs or charging systems.
System Integration and FirmwareCheck available system interfaces, firmware update support and the level of technical assistance for integration.

Not every SECC supports the same functions. Manufacturers should confirm the exact protocol version and supported features for each product model.

What Should You Check When Selecting an ISO 15118-20 SECC?

If you are developing an EV charging station for international markets, consider these points before choosing an SECC supplier:

Protocol compatibility: Confirm that the controller supports ISO 15118-20 itself, rather than only ISO 15118-2 or DIN 70121.

Charging application: Check whether the product is designed for your AC or DC charging architecture and the relevant CCS application.

Security functions: Ask about TLS implementation, certificate handling, and Plug & Charge support where required.

Interoperability testing: Request test reports or records showing compatibility with relevant EV models and charging systems.

Integration and technical support: Check available interfaces, firmware updates, documentation, and support for integration with your existing charger controller.

For a supplier reference, see our guide to Top 10 SECC Manufacturers in China.

Why Does ISO 15118-20 Matter for the Future of EV Charging?

ISO 15118-20 is relevant to several developments in the EV charging industry:

  • Smart Charging: More advanced communication between vehicles and charging equipment helps coordinate charging requirements.

  • Plug & Charge: Automated authentication can simplify the charging experience.

  • Bidirectional Charging: Standardized communication procedures provide a foundation for V2G and other bidirectional energy applications.

As these applications develop, SECC controllers and other communication components will play an increasingly important role in EV charging system design.

Frequently Asked Questions

Q1. What is the main difference between ISO 15118-2 and ISO 15118-20?

ISO 15118-20 is the second-generation communication standard. It expands the communication framework and defines bidirectional power transfer procedures, as well as additional communication functions.

Q2. Does ISO 15118-20 support V2G?

Yes. It defines communication procedures for bidirectional power transfer. However, V2G also requires compatible vehicles, bidirectional power conversion equipment, and suitable grid-side infrastructure.

Q3. Does an EV charger need a new SECC to support ISO 15118-20?

Not necessarily. It depends on the existing SECC hardware, firmware, communication architecture, and whether the manufacturer can provide a validated upgrade. Some systems may require a new controller.

Q4. Is ISO 15118-20 mandatory for all EV charging stations?

No. Requirements depend on the target market, project specifications, and applicable regulations. Manufacturers should check the requirements for their intended applications.

发表评论

您的邮箱地址不会被公开。 必填项已用 * 标注